This is a discussion on hp4192a - labview ; Hi,I downloaded the driver for HP4192a.LLB from NI website. Is there anyone who can tell me how to use the Log Sweep mode? Thanks....

+ Reply to Thread
Results 1 to 7 of 7

hp4192a

  1. Default hp4192a

    Hi,I downloaded the driver for HP4192a.LLB from NI website. Is there anyone who can tell me how to use the Log Sweep mode? Thanks.

  2. Default Re: hp4192a

    Have you checked the instrument's manual? Or are you asking about the VI's inputs or operation?

  3. Default Re: hp4192a

    Hi, Yes, I mean how to control the machine with the downloaded VI. Do you think we need to modify the VI so that the Log Sweep function will work? If so, can you give me some suggestions? As a matter of factor, I do not know Labview much. Your help will be highly appreciated.

  4. Default Re: hp4192a

    Have you found the "HP4192A Sweep" VI in that library? That's the one that sweeps the instrument. The controls on it are fairly self-explanatory. Set the log sweep slider to "ON" and set the sweep range, and whether or not you're sweeping bias or frequency. Not much more to it than that. The VIs themselves are not written all that well, and it's clear they're old since they use the old GPIB commands. Thus, I can't really speak to their accuracy.Write back if you have further problems.To learn more about LabVIEW it is recommended that you go through the tutorial(s) and look over the material in the NI Developer Zone's <a href="http://zone.ni.com/devzone/cda/tut/p/id/5054" target="_blank">Learning Center</a> which provides links to other materials and other tutorials. You can also take the <a href="http://www.ni.com/academic/lv_training/how_learn_lv.htm" target="_blank">online courses</a> for free.

  5. Default Re: hp4192a

    Thank you for your prompt response. I did switch the Log Sweep ON in both HP4192A Sweep.vi and HP4192A Sweep SUBVI.vi Front Panels. I also set the frequency range and step. It still scan in Linear Mode. Do you know why? By the way,&nbsp; can you tell me how to deal with STEP in Log Sweep mode?

  6. Default Re: hp4192a

    Are you trying to run the "HP4192A Example"? If so, that calls the "HP4192A Sweep" VI, but it sets the sweep to linear. Even if you have the "HP4192A Sweep" VI open and you set the front panel control to "LOG", when you run the "HP4192A Example", it tells the "HP4192A Sweep" VI to run in "LINEAR" mode. You either need to run the "HP4192A Sweep" VI on its own, or change the "HP4192A Example" so that you can have a control on the front panel that sets the mode:<img src="http://forums.ni.com/attachments/ni/170/313448/1/HP4192A%20Example_BD.png"> Adding a control to the "HP4192A Example" to control the sweep mode. As for your question on the step value: I don't understand your question. That's just the step size for the sweep. You should check the instrument's manual to determine if you need to make this any specific value for sweeping in log mode. Message Edited by smercurio_fc on 04-03-2008 09:28 AM


    HP4192A Example_BD.png:
    http://forums.ni.com/attachments/ni/...3448/1/HP4192A Example_BD.png

  7. Default Re: hp4192a

    Thank you very much. I will try to modify the vi according to your idea.